Downlight Cover Dimensions
Warnings (Must be read prior to Installation)
- Ensure that Mitt being utilised has 10mm minimum clearance from light fitting
- Before the install of a Mitt product ensure that the power supply is isolated from the main switch.
- Non ventilated Mitt install is recommended for gimble fittings, not fixed head fittings, or fittings with no openings to the living area.
- Do not carry out any modifications to the Mitt without consulting Efficiency Matrix.
- Ensure that LED lamps or Efficiency Matrix Certified lamps are utililised.
- Ensure that installation method (Above and Below ceiling) is carried out accordingly.
- Ensure that installation method for transformer (Above and Below Ceiling) is carried out accordingly. Transformer is not to be installed within Mitt area.
- Ensure that area within Mitt is clear of dirt and debris prior to installation.
- Halogen Mitt installations must have warning label (Supplied) on the lamp holder installed.
- All downlight fittings must adhere to the Lamp requirements.
- All electrical 240V wiring work must be undertaken by a licensed electrician.
- For fittings that have structural members in the way of the Mitt, mastic must be used but the Mitt must clear the fitting by at least 10mm.
- Downlight Mitt must be installed with the supplied wire fixing into plaster in order to be certified with a fire rating.
- Ventilated Basic Downlight mitts must not have any insulation covering the Mitt

| Dimension | Mitt Downlight cover | ESV Incandescent (No Mitt) | ESV Halogen (No Mitt) |
|---|---|---|---|
| A – Clearance above Luminaire | 0 mm | 50 mm | 200 mm |
| B – Side clearance to structure member | 0 mm | 100 mm | 200 mm |
| C – Clearance to thermal insulation | 0 mm | 50 mm | 200 mm |
| D – Clearance to supply transformer | 0 mm | 50 mm | N/A |
| Mitt clearance to Light fitting | 5 mm | N/A | N/A |
Mitt Install Reference Guide
| Ceiling Retrofit | With Electronic Transformer | With Ironcore Transformer | Fixed Head (73mm) | Gimble Fitting (90mm) | 240V recessed (150mm) | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Install Method | Below | Above | Below | Above | Below | Above | Below | Above | Below | Above |
| Basic Mitt | Yes | Yes | No | Yes | No | Yes | Yes | Yes | Yes | Yes |
| LED Mitt | Yes | Yes | No | Yes | No | No | Yes | Yes | No | No |
| Loft Mitt | No | Yes | No | Yes | No | Yes | No | Yes | Yes | Yes |