Support

Downlight cover Specifications

Downlight Cover Dimensions

Warnings (Must be read prior to Installation)

  1. Ensure that Mitt being utilised has 10mm minimum clearance from light fitting
  2. Before the install of a Mitt product ensure that the power supply is isolated from the main switch.
  3. Non ventilated Mitt install is recommended for gimble fittings, not fixed head fittings, or fittings with no openings to the living area.
  4. Do not carry out any modifications to the Mitt without consulting Efficiency Matrix.
  5. Ensure that LED lamps or Efficiency Matrix Certified lamps are utililised.
  6. Ensure that installation method (Above and Below ceiling) is carried out accordingly.
  7. Ensure that installation method for transformer (Above and Below Ceiling) is carried out accordingly. Transformer is not to be installed within Mitt area.
  8. Ensure that area within Mitt is clear of dirt and debris prior to installation.
  9. Halogen Mitt installations must have warning label (Supplied) on the lamp holder installed.
  10. All downlight fittings must adhere to the Lamp requirements.
  11. All electrical 240V wiring work must be undertaken by a licensed electrician.
  12. For fittings that have structural members in the way of the Mitt, mastic must be used but the Mitt must clear the fitting by at least 10mm.
  13. Downlight Mitt must be installed with the supplied wire fixing into plaster in order to be certified with a fire rating.
  14. Ventilated Basic Downlight mitts must not have any insulation covering the Mitt

DimensionMitt Downlight coverESV Incandescent (No Mitt)ESV Halogen (No Mitt)
A – Clearance above Luminaire0 mm50 mm200 mm
B – Side clearance to structure member0 mm100 mm200 mm
C – Clearance to thermal insulation0 mm50 mm200 mm
D – Clearance to supply transformer0 mm50 mmN/A
Mitt clearance to Light fitting5 mmN/AN/A

Mitt Install Reference Guide

Ceiling RetrofitWith Electronic TransformerWith Ironcore TransformerFixed Head (73mm) Gimble Fitting (90mm)240V recessed (150mm)
Install MethodBelowAboveBelowAboveBelowAboveBelowAboveBelowAbove
Basic MittYesYesNoYesNoYesYesYesYesYes
LED MittYesYesNoYesNoNoYesYesNoNo
Loft MittNoYesNoYesNoYesNoYesYesYes